No Client Config; Event Config - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

12.1.8.3

no client config

Description
With this command, you disable one of the clients that processes or forwards the messages
of the device.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
syslog
trap
email
all
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the show events config command.
You enable the function with the client config command.
12.1.8.4

event config

Note
The IE switch does not support all parameters, refer to the section "Features not supported
(Page 30)".
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Disables the client that sends the messages to the Syslog server
Disables the client that sends the SNMP traps
Disables the client that sends the e-mails
Disables all clients at once
Diagnostics
12.1 Event and fault handling
555

Hide quick links: