The parameters have the following meaning:
Parameter
interface-type
interface-id
reset
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
Link Check is activated on the port.
Further notes
You disable the function with the no linkcheck command.
You can display the status of this function and other information with the show linkcheck
command.
With the event config command, you can configure so that you are informed of a status
change by a message.
8.4.6.2

no linkcheck

Description
With this command, you disable the Link Check function on a port.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
no linkcheck {<interface-type> <interface-id>}
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Type or speed of the interface
Module no. and port no. of the interface
After resetting Link Check, the function
is restarted on the port and the statistics
are reset.
If you use the reset parameter, the re‐
set must be performed on both connec‐
tion partners within 30 s.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
Range of values / note
Enter a valid interface.
When you use the reset param‐
eter, loops can form temporarily
resulting in a loss of data traffic.
The loop is automatically cleared
again.
If this is not acceptable for your ap‐
plication, reset Link Check by pull‐
ing the connecting cable and plug‐
ging it in again.
401