Commands In The Events Configuration Mode; Add Log - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

If you do not select any parameters from the parameter list, the default value is used.
Result
Following the test phase, the result is displayed.
The value for the distance has a tolerance of +/- 1 m.
12.1.8

Commands in the Events configuration mode

This section describes commands that you can call up in the EVENTS configuration mode.
In the Global configuration mode, enter the events command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
● If you exit the EVENTS configuration mode with the exit command, you return to the
Global configuration mode.
● If you exit the EVENTS configuration mode with the end command, you return to the
Privileged EXEC mode.
12.1.8.1

add log

Description
With this command, you create an entry in the log.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
add log <log-entry>
The parameter has the following meaning:
Parameter
log-entry
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Entry in the logbook
Diagnostics
12.1 Event and fault handling
Range of values / note
max. 150 characters