Cabletest Interface - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Diagnostics
12.1 Event and fault handling
cli(config-events)#
Further notes
You exit the EVENTS configuration mode with the command end or exit.
12.1.7.2

cabletest interface

Description
With this command, you enable the cable test for the specified interface.
Note
Wire pairs
Wire pairs 4-5 and 7-8 of 10/100 Mbps network cables are not used.
The wire pair assignment - pin assignment is as follows (DIN 50173):
Pair 1 = pin 1-2
Pair 2 = pin 3-6
Pair 3 = pin 4-5
Pair 4 = pin 7-8
Requirement
● The interface has no active data traffic.
● You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call up the command without parameters or with the following parameter assignment:
cabletest interface <interface-type> <interface-id> [force]
The parameters have the following meaning:
Parameter
interface-type
interface-id
force
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
552
Description
Type of interface
Interface identifier
Forces a link down during the test
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
Enter a valid interface.
Necessary parameter if there is a
link up on the interface.