Interface Range - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

● You cannot use guest VLAN.
● The VLAN assignment cannot be adopted from the RADIUS server.
● You cannot configure the port type.
● Defined access rules must be valid for all VLANs: authorized-manager ip-source
Further notes
You can display the status of this function and other VLAN information with the show vlan
device info command.
6.1.2.2

interface range

Description
With this command, you can put several interfaces or the interfaces of VLANs together and
configure them together. The configurations are valid for all interfaces of the specified range.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
interface range
(
{<interface-type> <0/a-b,0/c,...>}
{vlan <vlan-id(1-4094)> - <vlan-id(2-4094)>}
)
The parameters have the following meaning:
Parameter
interface-type
0/a-b, 0/c,...
vlan
vlan-id
vlan-id
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you want to address several VLANs with this command, you must insert a blank before and
after the hyphen, for example interface range vlan 5 - 10.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Keyword for an interface
Module no. and port no. of the interface
Keyword for a VLAN connection
Number of the addressed VLAN
Number of the addressed VLAN
Network structures
6.1 VLAN
Range of values / note
Enter a valid interface.
-
1 ... 4094
2 ... 4094
173