Network structures
6.1 VLAN
Syntax
Call up the command with the following parameters:
priority <prio (0-7)>
The parameter has the following meaning:
Parameter
prio
Result
The VLAN has been assigned a priority.
Further notes
You reset the priority to the default value with the no priority command.
You enable the priority with the priority-enable command.
You disable the priority with the no priority-enable command.
You display the current priority with the show vlan command.
You configure the assignment of the priority to a queue with the cos-map command.
6.1.4.6

no priority

Description
With this command, you reset the priority of the VLAN back to the default value.
Requirement
You are in the VLAN Configuration mode.
The command prompt is as follows:
cli(config-vlan-$$$)#
Syntax
Call the command without parameter assignment:
no priority
Result
The priority of the VLAN is reset to the default value.
198
Description
Value of the priority
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
0 ... 7
Default: 0
Configuration Manual, 07/2017, C79000-G8976-C361-06