Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
fmp power-loss [req { <integer(0-0)> | - <integer(1-55)>}] [dem
{ <integer(0-0)> | - <integer(1-55)>}]
The parameters have the following meaning:
Parameter
req
dem
Result
The limits for monitoring the power loss are defined.
Further notes
You enable this function with the fmp command.
You disable this function with the no fmp command.
You display the status of this function and other information with the and show fmp limit
commands.
You define the limit values for the received power with the command fmp rx-power.
12.2.2.4

fmp rx-power

Description
With this command, you specify the limit values for monitoring the received power per port.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Specify the value at which you are informed of the pow‐
er loss of the connection by a message of the severity
level "Warning"
Specify the value at which you are informed of the pow‐
er loss of the connection by a message of the severity
level "Critical"
Range of values / note
0 ... -55 dB
Default: -50 dB
If you enter the value "0", the power loss
is not monitored.
0 ... -55 dB
Default: -55 dB
If you enter the value "0", the power loss
is not monitored.