No Spanning-Tree Mst Instance-Id Root - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Parameter
primary
secondary
Result
The function of the device is specified.
Further notes
You disable the root bridge with the no spanning-tree mst instance-id root
command.
You display this setting and other information with the commands that start with show
spanning tree ....
6.3.4.7

no spanning-tree mst instance-id root

Description
With this command, you disable the "root bridge" function on the device.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree mst{instance-id<instance-id(1-64)>}root
The parameters have the following meaning:
Parameter
instance-id
instance-id
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
The priority of the device is set to a low value so that the
device can become the root bridge (primary) of the Span‐
ning Tree instance. The lower the value, the higher the
priority.
The priority of the device is set to a low value so that the
device becomes the substitute root bridge (secondary) of
the Spanning Tree instance. If the root bridge (primary)
fails, the substitute root bridge (secondary) takes over the
task of the root bridge without delay.
Description
Keyword for the instance
Number of the instance
Network structures
6.3 Spanning Tree
Range of values / note
The priority is set to the val‐
ue 24576.
The priority is set to the val‐
ue 28672.
Range of values / note
-
1 ... 64