Network protocols
7.5 SNMP
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is blocked.
Further notes
You release write access for SNMPv1 and SNMPv2 PDUs with the no snmp v1-v2
readonly command.
7.5.2.19

no snmp v1-v2 readonly

Description
With this command, you enable write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is enabled.
Further notes
You block write access for SNMPv1 and SNMPv2 PDUs with the snmp v1-v2 readonly
command.