Severity - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Diagnostics
12.1 Event and fault handling
12.1.8.6

severity

Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
mail
log
syslog
info
warning
critical
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the no severity command.
You display the status of this function and other information show events severity
560
Description
Specifies the threshold value for send‐
ing system event messages by e-mail.
Specifies the threshold value for enter‐
ing system event messages in the log
table.
Specifies the threshold value for enter‐
ing system event messages in the Sy‐
slog file.
System events are processed as of the
severity level "Information".
System events are processed as of the
severity level "Warning".
System events are processed as of the
severity level "Critical".
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
-
-
-
-
-
-
Configuration Manual, 07/2017, C79000-G8976-C361-06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents