Radius-Server - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Result
The RADIUS authentication is deactivated.
Note
The login is possible only with a local user name and password. If the local logon fails, there
is no authentication via a RADIUS server.
Further notes
You enable the authentication via a RADIUS server with the login authentication
command.
11.2.2.3

radius-server

Description
With this command, you configure a RADIUS server entry on the RADIUS client.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
radius-server ipv4 <ipv4-address> [auth-port <portno(1-65535)>]
[retransmit <1-254>][key <secret-key-string>][primary] [{login |
dot1x | login-dot1x}] [test]
The parameters have the following meaning:
Parameter
ipv4
ipv4-address
auth-port
portno
retransmit
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Keyword for an IPv4 address.
Value for the IPv4 address of the Syslog
server
Keyword for the UDP port number for
authentication
Number of the port
Keyword for the number of connection
retries
Security and authentication
11.2 RADIUS client
Range of values / note
-
Enter a valid IPv4 address.
-
1 ... 65535
Default: 1812
-
509