Configuration

3.3 Reset and Defaults

3.3
Reset and Defaults
This section describes commands for restarting the device and for restoring the original
configuration.
3.3.1

restart

Description
With this command, you restart the device.
Select one of the following configuration settings:
● Device restart with the current configuration
● Device restart with the factory configuration settings.
● Device restart with the default settings of the PROFINET IO profile.
● Device restart with the default settings of the EtherNet/IP profile.
● Device restart with the default settings of the Industrial Ethernet profile.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
restart [{factory | pnio | ethernetip | ie}]
The parameters have the following meaning:
Parameter
Description
without parame‐
The system restarts with the current
ters
configuration
Restores the factory settings of the
factory
device and restarts the device.
The factory settings depend on the
device.
102
Range of values / note
● You can only restart the device with administrator privileges.
● A device should only be restarted by this CLI command or the
corresponding buttons in the WBM and not by a poer cycle on
the device.
● By resetting all the settings to the factory settings, the IP address
and the passwords are also lost. Following this, the device can
only be accessed via the serial interface, using the Primary
Setup Tool or using DHCP.
● With the appropriate attachment, a previously correctly
configured device can cause circulating frames and therefore
the failure of the data traffic.