10.4.2

Commands in the interface configuration mode

This section describes commands that you can call up in the interface configuration mode.
Depending on the Interface selected, various command sets are available.
In the Global configuration mode, enter the interface command to change to this mode.
Commands relating to other topics that can be called in the interface configuration mode can
be found in the relevant sections.
● If you exit the Interface configuration mode with the exit command, you return to the Global
configuration mode.
● If you exit the Interface configuration mode with the end command, you return to the
Privileged EXEC mode.
10.4.2.1

flowcontrol

Description
The flow control function monitors a connection at the receiving end to make sure that not
more data is received than can be processed. If flow control detects a threat of data overflow,
the partner at the sending end is sent a signal to stop transmitting.
With this command, you configure the flow control function for an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
flowcontrol {on|off}
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Load control
10.4 Flow control