Show Events Faults Status; Show Startup-Information - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
show events faults config [{power|link}]
The parameters have the following meaning:
Parameter
power
link
If no parameters are specified, the settings for both error monitoring functions are displayed.
Result
The current configuration of the selected error monitoring function is displayed.
12.1.3.4

show events faults status

Description
This command shows the status messages of fault monitoring of the power supply and network
connections.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show events faults status
Result
A table with the status messages of the error monitoring functions is displayed.
12.1.3.5

show startup-information

Description
This command shows the startup information.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Monitoring of the power supply for power outage
Monitoring of the network connections for a change in the connection status
Diagnostics
12.1 Event and fault handling
545