6.3.4.4

no spanning-tree compatibility

Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is RST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the spanning-tree compatibility command.
You can display the status of this function and other information with the show spanning
tree detail command.
6.3.4.5

spanning-tree mst configuration

Description
With this command, you change to the MSTP configuration mode.
Requirement
● MSTP is enabled
● Compatibility mode: MSTP
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#