Siemens SCALANCE XC-200 Configuration Manual page 349

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Requirement
● An SNMP group has been created
● The access to the group is configured with snmp access
● You are in the Global Configuration mode.
The command prompt is:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp view <ViewName> <OIDTree> [mask<OIDMask>] {included|excluded}
The parameters have the following meaning:
Parameter
ViewName
OIDTree
mask
OIDMask
View type
Storage type
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP view is configured.
Further notes
You delete the view with the no snmp view command.
You display the configured SNMP tree views with the show snmp viewtree command.
You display the SNMP group access rights with the show snmp group access command.
You configure the SNMP group access rights with the snmp access command.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
[{volatile|nonvolatile}]
Description
Name of the SNMP view
Object ID
Keyword for the OID mask
Mask that filters access to the elements
of the MIB tree
Specifies whether the filtered elements
are used or excluded.
Specifies whether the settings remain
following a restart.
Network protocols
7.5 SNMP
Range of values / note
max. 32 characters
Path information of the MIB tree
-
A series of "0" and "1" separated
by dots in keeping with the path in‐
formation of the MIB tree
● included (Default)
● excluded
● volatile:
The settings are lost after a
restart
● nonvolatile:
The settings are retained after
a restart (default).