Diagnostics
12.5 Port Mirroring
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command for the port to be monitored with the following parameter assignment:
no monitor session <session-id(1-1)> source
{interface <interface-type><interface-id>} [{rx|tx|both}]}
The parameters have the following meaning:
Parameter
session-id
interface
interface-type
interface-id
rx
tx
both
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you do not select any parameters from the parameter list, the default value (both) is used.
Result
The source for the mirroring of a port is deleted.
Further notes
You configure the source for mirroring a port with the monitor session ... source
command.
You end and delete a session with the no monitor session command.
You display the configuration settings with the show monitor session command.
12.5.2.9

no monitor session

Description
With this command, you delete the monitor session.
596
Description
Number of the session
Keyword for a an interface description
Type or speed of the interface
Module no. and port no. of the interface
Received data traffic will be mirrored
(received)
Transmitted data traffic will be mirrored
(transmitted)
Received and transmitted data traffic
will be mirrored
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
1
-
Enter a valid interface.
-
-
-
Configuration Manual, 07/2017, C79000-G8976-C361-06