7–6: Perf Real-Time Parameters
7–6a
7–6b
Here you can assign controllers to KARMA
Performance Real-Time Parameters (Perf. RTP) outside
of the GE Real-Time Parameters that control the
internal settings of the GE. Examples include the
KARMA Key Zone parameters (Program 7-1b) and
KARMA Control and Trigger parameters (Program 7-
3, 7-4).
By assigning these to KARMA SLIDERS 1–8 and
KARMA SWITCHES 1–8 etc., you can control them in
real-time while you play.
In Perf Real-Time Parameters 1–8, if you select a
parameter by "Group" and "Parameter" and On
(checked) "Module A," that parameter can no
longer be edited as a KARMA Key Zone parameter
(Program 7–1b) or KARMA Control and Trigger
parameter (Program 7–3,7–4).
7–6a: Program Name and Tempo
For descriptions of these parameters, please see "7–2a:
Program Name and Tempo" on page 100.
7–6b: Perf Real-Time Parameters
You can set up 8 different Performance Real-Time
Parameters, each of which has an identical set of
parameters, as described below.
Real-Time Parameters 1...8
Group
Selects the group of parameters that you wish to
choose a "Parameter" from. The KARMA parameters
are divided into six groups.
112
[
Off, PE, Mix, Control, Trigger,
Key Zones, Random Seeds
Parameter
Indicates the parameter that you wish to assign. The
parameters that can be selected will differ according to
the "Group" setting, above.
Min (Minimum Value)
This sets the parameter value when the selected
controller is at its minimum point—for instance, when
a slider is at the bottom of its throw. Note that you can
reverse the action of the controller by setting this to be
higher than the MAX value, below.
The available values will depend on the selected
parameter. When a parameter is selected, the
minimum parameter value will be set as the default.
Max (Maximum Value)
This sets the parameter value when the selected
controller is at its maximum point—for instance, when
a slider is at the top of its throw. The available values
will depend on the selected parameter.
Value
Specifies the value of the selected KARMA parameter.
If you turn on "A (Module A)" and select "Parameter,"
this will be set as the current value of the parameter
(set in 7–3 and 7–4). The value you specify here will be
the center value when you use "Assign" to control the
parameter from a KARMA SLIDER, etc. The value will
not be available when assigning to Switches or Slider
(SW).
]