1–1c: MIDI Filter
Enable Program Change
On (checked): Program changes will be transmitted
and received.
In Program mode (P0: Play), the program will be
switched when a program change message is received
on the global MIDI channel specified by MIDI
Channel (1–1a). When you switch programs, a
program change message will be transmitted on the
global MIDI channel.
In Combination mode (P0: Play), the combination will
be switched when a program change message is
received on the global MIDI channel. However, it is
possible to set the "Enable Combination Change"
parameter so that the combination is not switched.
When a program change is received on the channel
specified for each timbre by MIDI Channel
(Combination 2–1a), the program of that timbre will be
switched. However, the program changes for each
timbre will be affected by the setting of the "Enable
Program Change" parameter (Combination 3–1a).
When you switch combinations, a program change
message will be transmitted on the global MIDI
channel, and also transmitted simultaneously on the
channel of timbres whose Status (Combination 0–1b,
2–1a) is set to EXT or EX2.
In Sequencer mode, incoming program change
messages on a channel that corresponds to a track
whose Status (Sequencer 2–1a) is set to INT or BTH
will switch programs on that track. When you select a
song or playback sequencer data, program changes
will be transmitted on the channels of tracks whose
Status is set to BTH, EXT, or EX2.
Off (unchecked): Program changes will not be
transmitted or received.
Bank Change
On (checked): The Bank Select control change message
will be transmitted together with program change
messages. This is valid when "Enable Program
Change" is checked.
Clock: External
MIDI IN
"MIDI Clock": Internal
"Enable Start/Stop Out
MIDI OUT
in Prog/Combi": On
[Off, On]
[Off, On]
Global P1: MIDI
Off (unchecked): Bank Select messages will not be
transmitted or received.
When recording on the internal sequencer, bank select
messages will be recorded regardless of this setting.
However for playback, this setting will apply.
Combination Change
On (checked): When in Combination P0: Play, an
incoming program change message on the global MIDI
channel set by MIDI Channel (1–1a) will switch
combinations.
This is valid when "Enable Program Change" is
checked.
An incoming program change on a channel other than
the global MIDI channel will switch the program of
any timbre that matches that MIDI channel.
Off (unchecked): An incoming program change
message on the global MIDI channel will switch the
program of any timbre whose MIDI Channel
(Combination 2–1a) matches the global MIDI channel.
The combination will not be switched.
The program changes for each timbre will be affected
by the setting of the "Enable Program Change"
parameter (Combination 3–1a).
Enable After Touch
On (checked): MIDI after touch messages will be
transmitted and received.
Off (unchecked): MIDI after touch messages will
neither be transmitted nor received.
When recording sounds that do not require the use of
after touch, you can uncheck this parameter to save
memory.
This setting has no effect when you use the internal
sequencer to playback sequence data that was
recorded with after touch data; i.e., after touch will be
transmitted via MIDI.
The OASYS's keyboard transmits only channel after
touch; it does not transmit polyphonic after touch.
However, since the OASYS does support polyphonic
after touch as an Alternate Modulation Source (AMS),
it can receive polyphonic after touch to control
individual notes.
Enable Control Change
On (checked): Control change messages will be
transmitted and received.
Off (unchecked): Control change messages will
neither be transmitted nor received.
This setting has no effect when you use the internal
sequencer to playback sequence data that was
recorded with control change data; i.e., the control
changes previously recorded into the sequencer will be
transmitted via MIDI.
Enable Exclusive
On (checked): System exclusive data will be
transmitted and received.
Check this if you want to edit the OASYS from a
connected computer, or if you want to allow bi-
directional editing.
1–1: MIDI
[Off, On]
[Off, On]
[Off, On]