Ms-20Ex Tone Adjust - Korg Electronic Keyboard Parameter Manual

Korg electronic keyboard user manual
Table of Contents

Advertisement

MS-20EX Tone Adjust

MS-20EX Tone Adjust Default Settings
VCO1
VCO1
VCO2
VCO2
Waveform
Waveform
Waveform
Waveform
EG1
EG1
EG1
EG1
Delay
Delay
Attack
Attack
Tone Adjust provides an elegant physical interface to
the MS-20EX's parameters. Most of the factory sounds
use the default layout, as shown above. You can also
customize the layout for individual sounds, if desired.
For more information about Tone Adjust, please see
"0–9f: Tone Adjust," on page 26.
Common Tone Adjust parameters
These parameters affect both EXi 1 and 2. Except as
noted below, the Common Tone Adjust parameters
behave as described under "Common Tone Adjust
Parameters," on page 28.
Filter Cutoff. (–99...+99, CC#74)
This scales the cutoff frequency of the lowpass filter. To
adjust the highpass filter, use the separate, MS-20EX-
specific Tone Adjust parameters.
Filter Resonance. (–99...+99, CC#71)
This scales the resonance (PEAK) of the lowpass filter.
To adjust the highpass filter, use the separate, MS-
20EX-specific Tone Adjust parameters.
Filter EG Intensity. (–99...+99, CC#79)
This scales the EG2/EXT knob for the lowpass filter.
Amp Velocity Intensity. (–99...+99)
Not supported.
Filter/Amp EG Attack Time.
(–99...+99, CC#73)
This scales the attack time of EG2, which is normalled
to both filter cutoff and amplitude.
MS-20EX Tone Adjust
HPF
HPF
HPF
HPF
HPF
HPF
Cutoff
Cutoff
Peak
Peak
EG2/Ext Mod
EG2/Ext Mod
EG1
EG1
EG2
EG2
EG2
EG2
Release
Release
Attack
Attack
Decay
Decay
Common Tone Adjust parameters
LPF
LPF
LPF
LPF
Cutoff
Cutoff
Peak
Peak
EG2/Ext Mod
EG2/Ext Mod
EG2
EG2
EG2
EG2
MG
MG
Sustain
Sustain
Release
Release
Waveform
Waveform
Filter/Amp EG Decay Time.
(–99...+99, CC#75)
This scales the decay time of EG2. It interacts with CC#
75.
Filter/Amp EG Sustain Level.
(–99...+99, CC#70)
This scales the sustain level of EG2.
Filter/Amp EG Release Time.
(–99...+99, CC#72)
This scales the release time of EG2.
Filter EG, Amp EG, and Pitch EG Attack Time, Decay
Time, Sustain Level, Release Time are not supported
by the MS-20EX.
Pitch LFO1 Intensity. (–99...+99, CC#77)
This scales the FREQUENCY MODULATION
MG/T.EXT knob. (Note that this controls the amount
of pitch modulation, but does not necessarily apply to
LFO1.)
MS-20EX Tone Adjust parameters
In addition to the Common Tone Adjust parameters
listed above, the MS-20EX adds a number of its own
parameters.
Note that these additional parameters are separate for
each EXi, as opposed to being shared by both EXi in
the Program.
LPF
LPF
Switches 7, 8, 15, 16:
Switches 7, 8, 15, 16:
LFOs 1, 2, 3, 4 Stop
LFOs 1, 2, 3, 4 Stop
MG
MG
Frequency
Frequency
305

Advertisement

Table of Contents
loading

Table of Contents