Instruction code
PED/APED/OPED
Device
DX
DY
S
1
S
2
Data type
S
1
S
2
Symbol
Explanation
1.
PED/APED/OPED correspond to LDP/ANDP/ORP. The only difference between PED/APED/OPED and
LDP/ANDP/ORP is that you must specify the bit device S
PED/APED/OPED is executed. Do not use the device S
result appears.
2.
APED connects the rising-edge detection of the contact in series.
3.
OPED connects the rising-edge detection of the contact in parallel.
4.
The system must scan PED/APED/OPED to get the state of the device. Changes to the device state are not
detected until PED/APED/OPED is scanned the next time
5.
You can use PED/APED/OPED only in function blocks.
6.
The state of the operation result is automatically output after the instruction is executed. You do not need to use an
input device for this.
Operand
Starting the rising-edge detection/Connecting the rising
,S
S
1
2
X
Y
M
SM
PED
S
1
APED
S
2
OPED
Q
2
repeatedly in the program. Otherwise, the wrong execution
2
C ha pt er 5 Bas ic I ns t r uc t i ons
Function
edge-detection in series/Connecting the rising-edge
detection in parallel
S
T
Specified device
For internal use
Output the state of the
operation result
in which to store the previous state of the contact when
C
HC
D
5 - 11