18. (Optional) Enter a string that should be added at the beginning of each packet:
(config)> serial port1 udp socketid backslash-escaped-string
(config)>
19. Configure the remote sites to which you want to send data. If you do not specify any
destinations, the IX10 send new data to the last hostname and port from which data was
received. To add a destination:
i. Add a destination:
(config)> add serial port1 upd destination end
(config serial port1 udp destination 0)>
ii. (Optional) Enter a description of the destination:
(config serial port1 udp destination 0)> description string
(config serial port1 udp destination 0)>
iii. Set the host name or IP address of the remote site to which data should be sent:
(config serial port1 udp destination 0)>hostname hostanme-or-IP-
address
(config serial port1 udp destination 0)>
iv. Set the port number of the remote site to which data should be sent:
(config serial port1 udp destination 0)> port port
(config serial port1 udp destination 0)>
20. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
21. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure Modbus mode

Modbus mode allows you to use the serial port for Modbus. See
To change the configuration to match the serial configuration of the device to which you want to
connect:
  Web
IX10 User Guide
Configure Modbus mode
Modbus
gateway.