Error Source
Code
I/O Board
393
I/O Board
394
I/O Board
395
I/O Board
396
I/O Board
397
I/O Board
398
I/O Board
399
I/O Board
400
I/O Board
401
I/O Board
454
I/O Board
455
I/O Board
456
Front panel
500
Front panel
501
Front panel
502
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
Internal
Global fault detected.
Error
Error
Internal board fault.
Error
Invalid node ID. Run unit
discovery to recover.
Error
Incorrect DSP type
detected. Cycle-power to
re-try.
Error
Invalid constants loaded
from EEPROM.
Error
Controller is not in
operational node.
Error
Transformer coupling
circuits hardware fault.
Error
Transformer coupling
circuits not detected.
Error
Remote inhibit was issued
from remote interface.
Error
Controller is not in
operational node.
Error
Missing controller node.
Error
Cannot read fault
information.
Warning
AC voltage setpoint was
automatically reduced to
0 Vrms.
Error
Frequency is too high to
enable xfmr coupling.
Error
Extended voltage range is
not allowed when
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
Hardware Fault
An inconsistency was
detected in the power
source's internal
communication network.
Internal Communication
Error. AUX I/O processor
not responding
Configuration Error.
Coefficients found are
invalid.
An inconsistency was
detected in the power
source's internal
communication network.
An inconsistency was
detected in the power
source's internal
communication network.
An inconsistency was
detected in the power
source's internal
communication network.
An inconsistency was
detected in the power
source's internal
communication network.
Resolution
Try recycling power. If
error persists, contact
customer service
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Try recycling power. If
error persists, contact
customer service
SANITIZE unit to restore
factory defaults
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.