10.8.5 Scope

The Scope function captures voltage and current waveforms at the output of the power source
on all phases. This screen allows a variety of captured waveforms to be displayed.
The following controls are available to customize the captured waveform display:
CONTROL
MEASUREMENT
PHASE
TIME UNIT
PERIODS
AUTO REFRESH
REFRESH PERIOD
REFRESH
EXPORT GRAPH
EXPORT DATA
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Purpose
Selects Voltage L-N, Voltage L-L, Current or Both Voltage & Current
Selects Phase A, B, C or all (ABC). Only visible in two or three phase mode.
Selects time scale in either TIME, SAMPLES or PHASE
Selects the number of periods to display. Range is 1~ 4
Turns AUTO REFRESH mode ON or OFF
Sets interval time for AUTO REFRESH mode in seconds. Range is 5 ~ 100.
Manual REFRESH button
Downloads image for displayed waveform(s). See sample below.
Downloads captured data points for displayed waveform(s) in csv format text
file. See sample below.
AFX SERIES® OPERATION MANUAL
LAN Interface Configuration
SECTION 10:
Sample
Degrees
Time[s]
1
0
2
0.7
3.91E-05
3
1.41
7.81E-05
4
2.11
0.000117
5
2.81
0.000156
6
3.52
0.000195
Phase A -
Voltage[V]
0
-0.12
0.05
0.02
-0.1
-0.03
0
Page 427 of 485