Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
MEASure:CURRent:PEAK#:MINimum:HOLD?
Returns the lowest measured peak hold current value for the selected
phase #. If no phase number is specified, returns the reading for all
phases. This reading accumulates the lowest recorded absolute peak
hold current until reset using the MEASure:CURRent:PEAK#:RESet
command.
<nr2>
MEAS:CURR:PEAK:MIN:HOLD?
1.0001, 0.8451, 0.4871
MEASure:CURRent:PEAK#:MAXimum?
Returns the highest measured peak current value for the selected
phase #. If no phase number is specified, returns the reading for all
phases.
<nr2>
MEAS:CURR:PEAK:MAX?
45.5845, 47.3213, 48,2234
MEASure:CURRent:PEAK#:MAXimum:HOLD?
Returns the highest measured peak hold current value for the
selected phase #. If no phase number is specified, returns the reading
for all phases. This reading accumulates the highest recorded
absolute peak hold current until reset using the
MEASure:CURRent:PEAK#:RESet command.
<nr2>
MEAS:CURR:PEAK:MAX:HOLD?
58.5845, 57.3213, 58,2234
MEASure:CURRent:PEAK#:RESet
This command resets all peak hold current readings for the selected
phase # to zero. If no phase number is specified, returns the reading
for all phases.to zero.
None
n/a
MEAS:CURR:PEAK1:RES
MEASure:CURRent:CREST#?
Returns the measured current crest factor for the selected phase #. If
no phase number is specified, returns the reading for all phases.
<nr2>
MEAS:CURR:CREST1?
2.1544