Pacific Power Source AFX Series Operation Manual page 462

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Error Source
Code
Front panel
107
Error
Front panel
108
Error
Front panel
109
Error
Front panel
110
Error
Front panel
111
Error
Front panel
115
Error
Front panel
116
Error
Front panel
117
Error
Front panel
118
Error
Front panel
119
Error
Front panel
120
Error
Front panel
121
Error
Front panel
122
Error
Front panel
124
Error
Front panel
125
Error
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
Error
Redundant segments
were combined.
Error
Redundant steps were
combined.
Error
Transient step mode not
available on UPC
compatible mode.
Error
System is about to
reboot.
Error
Cannot reboot system.
Error
Unable to renew the
DHCP lease. Changing to
Auto-IP mode.
Error
Failed starting firmware
update.
Error
Unable to execute this
action with output
enable.
Error
Frequency set point
cannot change due to
waveform saturation.
Error
Frequency set point
cannot change due to
user limit.
Error
Frequency not allowed in
"DC mode".
Error
Waveform set point
cannot change due to
waveform saturation.
Error
Cannot load program.
Run PROG:CHECK? for
more information.
Error
LAN interface not
available.
Error
Remote inhibit cannot be
disabled in this model.
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
Optimization. Segment
data received contained
redundant segments
which were removed
Optimization. List Step
data received contained
redundant steps which
were removed
Setting conflict. Step
mode only supported in
AFX mode.
Warning, Reboot
imminent
Soft reboot failed. Front
panel could not reboot
itself.
LAN Error. IP address
lease from DHCP expired
Firmware Update Error.
Unable to start firmware
update
Setting conflict.
Requested action not
possible with output ON
Setting conflict. In
extended voltage range,
frequency range is
restricted. Max peak
voltage is reduced
outside this range and if
there is a DC offset
programmed, the peak of
the voltage exceeds the
max. limit.
Setting conflict.
Frequency set point
outside User Limits
Setting conflict. No
frequency setting applies
in DC mode
Setting conflict. The crest
factor of the waveform
selected would result in a
peak voltage that exceeds
the max peak voltage
supported. Or combined
AC peak + DC
programmed exceeds
max peak voltage
Setting conflict
LAN Error. No LAN
connection
Remote Inhibit always
enabled. Unit was bought
Resolution
Not needed
Not needed
Switch to AFX mode or
use Segments
Wait
Try recycling power. If
error persists, contact
customer service
Renew IP lease of use
Auto IP mode
Check for correct
firmware image file and
version.
Turn output OFF
Reduce programmed
RMS and/or DC value.
Change User Limits or
frequency setting
Change to AC or AC+DC
mode
Reduce waveform crest
factor ratio or reduce
programmed RMS and/or
DC value.
Use PROG:CHECK?
Command to query
conflict details
Check connection to LAN
Connect Remote Inhibit
input as needed.
Page 462 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents