[SOURce:]STEP:REPeat <no, opt>
This command sets the number of repeat times for the ramp of the
step
No of repeats, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr1>, <cr>
STEP:MODE:REP 100
[SOURce:]STEP:REP?
<nr2>
STEP:REP?
100, NOR
[SOURce:]STEP:REPeat:MINimum?
This command returns lowest permissible set value for the STEP
length time setting.
<nr1>
STEP:REP:MIN?
0
[SOURce:]STEP:REPeat:MAXimum?
This command returns highest permissible set value for the STEP
length time setting.
<nr1>
STEP:REP:MAX?
65535
[SOURce:]STEP:REPeat:DEFault?
This command returns default set value for the STEP length time
setting.
<nr2>
STEP:REP:DEF?
1
[SOURce:]STEP:COUNT <no, opt>
This command sets the number of steps count.
No of step count, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr1>, <cr>
STEP:MODE:REP 12
[SOURce:]STEP:COUNT?
<nr2>
STEP:REP?
12, NOR