Pacific Power Source AFX Series Operation Manual page 466

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Error Source
Code
Front panel
188
Error
Front panel
189
Error
Front panel
190
Error
Front panel
191
Error
Front panel
192
Error
Front panel
193
Error
Primary Fault
200
Primary Fault
201
Primary Fault
202
Primary Fault
203
Primary Fault
204
Primary Fault
205
Primary Fault
206
Primary Fault
207
Primary Fault
208
Primary Fault
209
Primary Fault
210
Primary Fault
211
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
detected. Going to
inactive state.
Error
One or more units are not
energized or have a
failure.
Error
Incompatible node
detected.
Error
Master unit nodes not
found.
Error
Fast scan failed.
Error
Undetectable node exists.
Error
An invalid firmware type
exists.
Error
LLC primary/auxiliary
current peak limit
exceeded.
Error
LLC/PFC gate driver fault
or hardware OVP.
Error
Controller missed
heartbeats from master
front panel.
Error
LLC primary current
average limit exceeded.
Error
LLC auxiliary current
average limit exceeded.
Error
PFC current peak limit
exceeded.
Error
PFC DC bus voltage limit
exceeded.
Error
Gate driver fault
Error
Input buck switching
time.
Error
AC input current
exceeded RMS limit for
too long.
Error
Unbalanced current in
PFC boost converters.
Error
PFC efficiency protection.
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
Error during discovery.
Error with one or more
Auxiliary units found
during discovery
Error during discovery.
Error with one or more
Auxiliary units found
during discovery
Error during discovery.
One or more nodes in
Master unit not found
Error during discovery.
Fast scan discovery failed
An inconsistency was
detected in the power
source's internal
communication network.
Firmware Error. One or
more nodes report invalid
firmware type
Gate driver fault occurred
in Input Buck Converter.
Resolution
from System menu to
recover
Check all parallel cables
between units. Make sure
all units are powered on.
Run parallel unit
discovery from System
menu to recover
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Check for correct
firmware image file and
version.
Check for correct AC
input voltage connection.
Page 466 of 485