8.7.8

Current Protection Programming Commands

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
[SOURce:]PROTect[:RMS]:CURRent[:STATe] <ON|OFF>
This command enables or disables the rms current protection. If the
protection is tripped the power source output is disabled.
< ON | 1 | OFF | 0 >
<nr1> | <cr>
PROTect:CURRent ON
[SOURce:]PROTect[:RMS]:CURRent[:STATe]?
<nr2>
PROTect:CURRent?
1
[SOURce:]PROTect[:RMS]:CURRent:LEVel <LEVEL>
This command sets the rms current protection level.
< LEVEL >
<nr2>
PROT:CURR:LEVel 40.0
[SOURce:]PROTect[:RMS]:CURRent:LEVel?
<nr2>
PROT:CURR:LEV?
40.000
[SOURce:]PROTect[:RMS]:CURRent:LEVel:MINimum?
This command returns the minimum rms current protection level
setting.
PROT:CURR:LEV:MIN?
0.000
[SOURce:]PROTect[:RMS]:CURRent:LEVel:MAXimum?
This command returns the maximum rms current protection level
setting.
PROT:CURR:LEV:MAX?
41.667
[SOURce:]PROTect[:RMS]:CURRent:LEVel:DEFault?
This command returns the default rms current protection level
setting. This value will be a function of the power source model.
PROT:CURR:LEV:DEF?
41.667