[SOURce:]CONFIG:DC <b>
Selects alternative DC loop compensation mode for improved DC
transient response.
The effect of this command depends on the selected output mode as
follows:
AC Mode:
No effect
DC Mode:
Changes the DC loop compensation
AC+DC Mode:
No effect
Note: Available in units with Firmware revision 1.6.0 or higher.
< 0 | 1 >
( 0 = Normal loop, 1 = Faster Loop )
<b>
SOUR:CONFIG:DC 1
[SOURce:]CONFIG:DC?
<b>
CONFIG:DC?
0
[SOURce:]CONFIG:HFreq <b>
This command enables high-frequency output current protection
extension mode. In this mode, the protection for high frequency
content at the output of the power source is held off for up to 2
seconds to allow short time events to ride through without tripping
the normal protection mode.
Note: Available in units with Firmware revision 1.6.6 or higher.
< 0 | OFF | 1 | ON >
<b>
SOUR:CONFIG:HF 1
[SOURce:]CONFIG:HFreq?
<b>
CONFIG:HF?
1
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
( 0 = Off, 1 = On)