Command Syntax
Description
Parameters
Example
Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
RESET STATE
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
*OPC
The Operation Complete (OPC) command sets bit 0 in the Standard
Event Status Register when all pending operations have finished.
Optional: < BLOCK | 0 | NOBLOCK | 1>
*OPC
*OPC? < BLOCK | 0 | NOBLOCK | 1>
IEEE488.2 standard command. The parameter is optional.
The argument is optional, if it is not sent:
• In UPC compatible mode default argument will be NONBLOCK or
1.
• In normal mode default argument will be BLOCK or 0.
*OPC? BLOCK | 0
Returns 1 when all pending overlapped operations have been
completed. It can be used to cause the controller to wait for
commands to complete.
*OPC? NOBLOCK | 1
Returns 1 if all pending overlapped operations have been completed
or 0 if there are pending overlapped operations. It will not cause the
controller to wait for commands to complete. Pending overlapped
operations can be a transient or a soft start using ramp time/slew
rates.
<b>
*OPC?
1
*RST
RESET. The *RST command (reset) has the same effect as an IEEE-488
Device Clear bus command but can be used over the RS232C, USB or
LAN interface as well. This command resets the unit to its power on
default state.
None
n/a
FORM
3
VOLT:AC
0.0000
VOLT:DC
0.0000
CURR:AC
41.6667
CURR:DC
20.8333
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
VOLT:MODE
COUPLING
RANGE
AC
DC
AC
Page 387 of 485