Pacific Power Source AFX Series Operation Manual page 459

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Error Source
Code
Front panel
-256
Error
Front panel
-253
Error
Front panel
-240
Error
Front panel
-224
Error
Front panel
-222
Error
Front panel
-221
Error
Front panel
-203
Error
Front panel
-158
Error
Front panel
-138
Error
Front panel
-131
Error
Front panel
-113
Error
Front panel
-109
Error
Front panel
-108
Error
Front panel
-103
Error
Front panel
-102
Error
Front panel
53
Error
Front panel
54
Error
Front panel
56
Error
Front panel
57
Error
Front panel
58
Error
Front panel
59
Error
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
SCPI error
Execution error: File not
found.
SCPI error
Execution error: Media is
corrupted.
SCPI error
Execution error:
Hardware error.
SCPI error
Execution error: Illegal
parameter value.
SCPI error
Execution error:
Argument out of range.
SCPI error
Execution error: Conflict
in configuration setting.
SCPI error
Execution error:
Permission denied.
SCPI error
Command error: String
data is not allowed.
SCPI error
Command error: Numeric
suffix is invalid.
SCPI error
Command error: Numeric
suffix is out of range.
SCPI error
Command error:
Undefined header.
SCPI error
Command error: Invalid
number of parameters.
SCPI error
Command error:
Parameters error.
SCPI error
Command error: Invalid
separator.
SCPI error
Command error: Syntax
error.
Error
Error during firmware
update.
Error
Calibration coefficient
cannot be negative.
Error
Waveform name is not
available.
Error
Waveform file is not
available.
Error
Waveforms lengths are
different between
inverter controllers.
Error
Unit does not exist.
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
File specified does not
exist
Media used has been
corrupted
Unspecified Hardware
Error detected. Cause
unknown
Invalid parameter value
Argument passed exceeds
allowable range
Configuration setting
conflict
Read or Write access to
memory selected denied.
Some memory areas are
off limits
Passing string data when
string type is not
supported
Number suffix not valid
Suffix number passed
exceeds allowable range
Command Header not
defined
Invalid number of
parameters. Too few or
too many parameters are
being passed
Errors in parameters
Separator used is invalid
Syntax Error
Firmware Update Error.
Update may have failed
Negative Calibration
Coefficients are not
allowed
Waveform name
requested does not exist
Waveform register
selected is empty
Waveforms lengths are
not equal between three
phases
Unit selected cannot be
found
Resolution
Check for correct file
name
Reformat or replace
media
Try recycling power. If
error persists, contact
customer service
Check value
Adjust parameter to be
within valid range
Check configuration
settings
Check memory type or
permissions
Pass correct data type
Check value
Adjust suffix to be within
valid range
Check command
Check for correct no. of
parameters
Check parameter values
Use correct separator
character
Check syntax
Check for correct
firmware image file and
version.
Make sure cal coefficients
are positive values
Use existing waveform
name from waveform
library
Download valid
waveform data to
selected register
Check waveform data for
correct length
Try recycling power. If
error persists, contact
customer service
Page 459 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents