Pacific Power Source AFX Series Operation Manual page 248

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Query Format
Description
Parameters
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
PROGram:TT? [<nr1>][,<nr1>] [,<cr>]
This command returns the Transient Table settings of the program
number specified. The format in which the data is returned can be
specified with the first parameter.
If no program number is passed as a parameter, the selected program
data is returned. See PROG:NAME for the selected program. The steady
state table data is not returned.
If no memory type is specified, the transient table stored in the
selected memory type is returned. See PROG:MEMORY for the selected
memory type.
Option: STYLE [,<nr1]
0 = Human readable Style A (default if omitted)
1 = Human readable Style B
2 = Binary Data Format. Can be more useful to search for differences
between programs.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:TT? 1,2
-> transient table program data
Formats for transient table shown below are:
Style A:
3,1,1,100.0,100.0,60.000,0.000,1.000|2.000|3.000,1,0.0|120.0|240.0S
tyle B:
3,1,1,100.0,100.0,60.000,0.000,0.000,0.000,0.000,1.000,1.000,2.000,3.
000,1,1,1,1,0.0,120.0,240.0
Binary:
000070420000000000000000000000000000803F00000040000040400
000F0420000704301010100F401000000007042000000000000000000
0000000000803F00000040000040400000F0420000704301010100F40
10000
PROGram[:SELected]:TT? [,<nr1>] [,<cr>]
This command returns the Transient Table settings of the selected
program only. The steady state table data is not returned.
Option: STYLE [,<nr1]
0 = Human readable Style A (default if omitted)
1 = Human readable Style B
2 = Binary Data Format. Can be more useful to search for differences
between programs.
See PROGram:TT? Command for formats
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:TT? 1
-> transient table program data
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 248 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents