Error Source
Code
Front panel
172
Error
Front panel
173
Error
Front panel
174
Error
Front panel
175
Error
Front panel
176
Error
Front panel
180
Error
Front panel
181
Error
Front panel
182
Error
Front panel
183
Error
Front panel
184
Error
Front panel
185
Error
Front panel
186
Error
Front panel
187
Error
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
Error
Command not allowed
during power stage
firmware update.
Error
Cannot change Current
RMS Overload mode with
output enable.
Error
Strobe feature not
available in this model.
Error
Feature not available in
this model.
Error
Set points cannot be
changed while transient
program is running.
Error
Unknown processor type
detected. Run unit
discovery to recover.
Error
Undiscovered node
detected. Run unit
discovery to recover.
Error
Incorrect parallel unit
count
Error
Invalid processor type
Error
Daisy chain invalid type
Error
Undiscovered controller
node was detected.
Error
No master front panel
was detected.
Error
More than enabled
master controller is was
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
Notification. Firmware
update for Power Stage in
progress. Command not
allowed during this time.
Setting conflict. Current
RMS overload mode can
only be enabled with
output OFF
Function Strobe Output
not supported. Feature
not available
Feature not available.
Setting conflict.
Attempting to change
setting while transient
execution is in progress
Auxiliary unit not
recognized. One of more
auxiliary units were not
recognized during
discovery
An inconsistency was
detected in the unit
internal communication
network.
Setting conflict. Auxiliary
unit count does not
match expected count
setting
Auxiliary unit not
recognized
Error during discovery
An inconsistency was
detected in the power
source's internal
communication network.
Error during discovery.
No Master found
Error during discovery.
Too many masters
Resolution
Wait for all firmware
updates to be completed
Turn output OFF, then
enable Current RMS
Overload mode
Requires AUX I/O board
Requires AUX I/O board
Abort Transient Run or
wait for transient
execution to complete
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover or adjust
expected count to match
actual no of units
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Check all parallel cables
between units. Run
parallel unit discovery
Page 465 of 485