Output Power Connector Rating And Isolation; Wire Size; Connecting A Uut - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Safety Notices" before making any load connections.
7.1.1

Output Power Connector Rating and Isolation

Maximum rated output voltage:
Maximum Current Rating:
Connector Type:
Designated Use:
Isolation Rating:
Wire Stripping Length:
7.1.2

Wire Size

A major consideration in making load connections is the wire size. The minimum wire size is
required to prevent overheating and to maintain good regulation. It is recommended that
the wires are sized large enough to limit the voltage drop at the maximum current rating of
the AC power source to less than 0.5V per lead.
Wire size also depends on ambient temperature and total wires in the cable bundle. For
example, for the full 41.7 amp current capability of a single output, at an ambient
temperature of 30 °C, in a bundle of not more than three 75 °C rated wires, common
electrical codes would recommend AWG 8 size (~10 mm^2).
7.1.3

Connecting a UUT

When setting up for a new test and connecting any equipment to the AC power source,
proceed as follows:
1. Always make sure the AC power source is turned OFF at the POWER switch when
making any wire connections.
2. Check that the output of the equipment under test is OFF.
Note: Some power equipment's output may still be energized even if the equipment
has been turned off or its output is turned off. This is especially true for AC power
sources.
Note: When working with batteries, it is recommended to provide a suitable
disconnect relay or switch so the AC power source can be physically disconnected
from the battery for handling purposes.
3. Connect one end of the load wires to the output terminals on the rear panel.
4. Check the polarity of the connections and connect the other end of the load wires to
the input terminals of the equipment under test.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
SECTION 7:
300V rms AC, 425Vdc
60A
Phoenix Contact SPC 16/ 6-STF-10, 16 - 1711417
AC or DC Load Connection
600V
18 mm
Page 186 of 485