Pacific Power Source AFX Series Operation Manual page 464

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Error Source
Code
Front panel
155
Error
Front panel
156
Error
Front panel
157
Error
Front panel
158
Error
Front panel
159
Error
Front panel
160
Error
Front panel
161
Error
Front panel
162
Error
Front panel
163
Error
Front panel
164
Error
Front panel
165
Error
Front panel
166
Error
Front panel
167
Error
Front panel
168
Error
Front panel
169
Error
Front panel
171
Error
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Category
Error Message
Error
Trigger output not
available in this model.
Error
Trigger input not
available in this model.
Error
Filter size must be an odd
number.
Error
Voltage mode not
available in UPC
compatible mode.
Error
Waveform is unique in
UPC compatible mode.
Error
Phase is 180 for split in
UPC compatible mode.
Error
Voltage AC is unique in
UPC compatible mode.
Error
CSC is always disabled
during transient in UPC
compatible mode.
Error
Auto RMS is always
enabled in UPC
compatible mode.
Event
Warning: CSC is enabled
and Auto-RMS is disabled.
Output RMS may not be
regulated properly.
Event
Maximum AC voltage
limit was reduced due to
extended voltage range.
Error
Unable to set extended
voltage because
frequency is outside the
allowed range.
Error
Power limits were
reduced due to extended
voltage range.
Error
AC voltage set points
and/or AC voltage
maximum limit were
reduced due to extended
voltage range.
Error
Unable to update set
point because it is outside
the allowed range of
extended voltage mode
Error
Warning: Repeated
waveform alias.
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
Trigger Output not
supported. Feature not
available
Trigger Input not
supported. Feature not
available
Invalid Filter Number.
Filter size must be odd
number
Setting conflict. UPC
mode only supports AC
Mode
Setting conflict.
Requested waveform
supported in UPC mode
only
Setting conflict. Phase
angle 180 reserved for
Split phase mode in UPC
Mode
Setting conflict. UPC
mode only supports AC
Mode
Setting conflict. CSC
mode cannot be enabled
during transients
Setting conflict. Auto RMS
mode cannot be disable
in UPC mode
Notification. Load
regulation may be off
Notification. Extended AC
voltage range derating
implemented
Setting conflict. Extended
AC voltage mode
available over limited
frequency range
Setting conflict. Extended
AC voltage mode
available over limited
power range
Notification. Extended AC
voltage range derating
implemented
Notification. Extended AC
voltage range derating
implemented
Duplicate waveform Alias
name. Waveform alias
name already exists
Resolution
Requires AUX I/O board
Requires AUX I/O board
Change filter parameter
to even number
Change to AFX Mode
Change to UPC Mode
Change to AFX Mode
Change to AFX Mode
Change to AFX Mode
Change to AFX Mode
Change to AFX Mode
Adjust frequency to
within available range
Adjust load to within
available power range
Use different Alias
Page 464 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents