[SOURce:]PHASe#
This command programs the phase angle for the selected phase. A
phase reference (#) must be specified.
Note that unless external sync mode is used, the A phase (# = 1)
cannot be programmed is fixed at 0 degrees.
0.0 – 359.9
<nr2>
PHAS2 122.5
[SOURce:]PHASe#?
<nr2>
PHAS2?
122.5
[SOURce:]PHASe#:SLEW
This command sets slew rate for the phase angle for the selected
phase. A phase reference (#) must be specified.
Note that unless external sync mode is used, the A phase (# = 1) slew
rate cannot be programmed is fixed at 0 degrees.
0.01 – 359.91
<nr2>
PHAS3:SLEW 10.25
[SOURce:]PHASe#:SLEW?
<nr2>
PHAS3:SLEW?
10.2500
[SOURce:]PHASe:ROTation <b>
This command sets default phase rotation at power on. Available
settings are POSITIVE (1) or NEGATIVE (0). This setting effectively
swaps phases B and C and may be used to set the required phase
rotation for AC motors.
[ 0 | NEGative | 1 | POSitive]
0 = NEGATIVE
1 = POSITIVE
<b>
PHAS:ROT POS
[SOURce:]PHASe:ROTation?
<b>
PHAS:ROT?
1