Other Measurement Commands; Measurement Data Logging Commands - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

8.4.6

Other Measurement Commands

Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
8.4.7

Measurement Data Logging Commands

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
MEASure:TEMPerature:AMBient?
Returns the ambient temperature of the power source in degrees
celcius.
<nr1>
MEAS:TEMP:AMB?
24
MEASure:ALL#?
Returns 14 parametric measurements for the selected phase # as a
comma delimited string. The # is used to specify phase A, B or C using
1, 2 or 3 respectively. If phase reference is omitted, measurement
data for all three phases is returned. Value order for each phase is:
1. Frequency (repeats for each phase)
2. VLL AC+DC
3. VLL AC RMS
4. VLL DC
5. VLN AC+DC
6. VLN AC
7. VLN DC
8. I AC
9. I DC
10. POWER
11. APP POWER
12. I PEAK
13. PF
14. CF
Thus, each phase data set consists of 14 values. For all phases, a total
of 42 comma separated values are returned.
<nr2>,<nr2>,....,<nr2>,<nr2>
MEAS:ALL1?
1200.0000,519.5981,519.5981,0.0028,299.9990,299.9989,-
0.0007,0.1711,-0.0016,0.0000,0.0513,0.4849,0.0000,0.0000
MEASure:LOGger:START
Starts the logging of measurements process. The process consists of
taking measurements and saving them in a file. The log file can be
found in the "datalogger" folder and is a comma separated value
format (.csv) file. Measurements will be taken while the output is
enabled only.
None
n/a
MEAS:LOG:START
None
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 225 of 485