Scpi Status Registers - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

8.12.3 SCPI Status Registers

The STATus:OPERation and STATus:QUEStionable registers provide information about the
present mode of operation.
Transition of a CONDition bit to the true state causes the EVENt bit to be set true.
Unmasked ENABle bits allow an EVENt bit to be reported in the summary bit for that
EVENt register in the STATUS BYTE register.
Setting an ENABLe bit true, unmasks the corresponding EVENt bit.
Reading an EVENt register clears it.
All :STATUS registers are 16 bits (Figure 5.3).
The STATus:OPERation register provides information about the present mode of operation.
Relevant commands for the STATus:OPERation register are:
:STATus:OPERation:CONDition?
:STATus:OPERation:ENABle
:STATus:OPERation:ENABle?
:STATus:OPERation:EVENt?
The STATUS:QUESTIONABLE register provides information about errors and questionable
measurements.
Relevant commands for the STATUS:QUESTIONABLE register are:
:STATus:QUEStionable:CONDition?
:STATus:QUEStionable:ENABle
:STATus:QUEStionable:ENABle?
:STATus:QUEStionable:EVENt?
Refer to Figure 8-4, "SCPI Status Registers Model" for details on registers.