Figure 4-1: Output Voltage Distortion Into Full R Load As A Function Of Frequency - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

AC OUTPUT
Requires firmware 2.0.0 or higher.
Extended operation from 1200Hz to 3000Hz supported at reduced maximum voltage. Some specifications
exceptions apply. Requires firmware version 1.6.2 or higher. Refer to Figure 4-3 on page 32 and Figure 4-4 on
page 32.
Note 4: FREQUENCY PROGRAM RESOLUTION FOR EXPORT MODELS (-4LE, -2LE, -4AGE, -2AGE):
Per U.S.A. Bureau of Industry and Security, ECCN 3A225, frequency control is limited to no better than 0.2% at
frequencies of 600 Hz. or more for unrestricted export products. To meet that requirement, frequency
programming on all AFX-xxE models has three resolution ranges, which round the frequency to the nearest
increment, as defined in the table below.
Frequency Resolution for Export Models
Range
1.00 - 99.99 Hz
100-599.9 Hz
600 - 999 Hz
1000 - 3000 Hz
Note 5: Refer to AC Mode Voltage / Current rating charts Figure 4-6, Figure 4-10, Figure 4-7 and Figure 4-11 on
following pages.
Note 6: Actual output phase angles may be slightly different from programmed values for highly unbalanced three
phase load conditions, in particular at high frequency due to amplifier phase shift differences.

Figure 4-1: Output Voltage distortion into full R Load as a function of Frequency

Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Resolution
0.01 Hz
0.1 Hz
2.0 Hz
5.0 Hz
AFX SERIES® OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Page 29 of 485