7.3.13.2
Analog Inputs
Analog inputs allow parameters settings to be controlled using DC input signals. The
parameter to be controller by each of four available analog inputs can be assigned from the
front panel.
Available settings or read-outs and parameter ranges are:
CHANNEL
INPUT VOLTAGE
COMMAND
RANGE
GAIN
OFFSET
The Command parameter allows the user to assign the selected analog input to the
parameter that will be controlled by it. The list of available setting commands for these
inputs is shown below.
VOLT:AC
VOLT:AC1
VOLT:AC2
VOLT:AC3
The Gain and Offset parameters can be used to scale and shift the input value to the desired
range for min. and max. output.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
SECTION 7:
[ 1 | 2 | 3 | 4 ]
Displays read back voltage
Select command from dropdown list or OFF for none. See
table below
0.0000 to 10.000 V
Gain
Offset value
Analog Input Command Values
VOLT:DC
CURR:LIM
VOLT:DC1
CURR:LIM1
VOLT:DC2
CURR:LIM2
VOLT:DC3
CURR:LIM3
Table 7-4: AUX I/O Analog Input assignable Commands
AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
FREQ
KVA:LIM
PHAS2
KVA:LIM1
PHAS3
KVA:LIM2
OFF
KVA:LIM3
POW:LIM
POW:LIM1
POW:LIM2
POW:LIM3