Pacific Power Source AFX Series Operation Manual page 335

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
[SOURce:]INTHarmonic:STATe <b>
This command enables (1) or disables Inter Harmonics mode. When
off, no interharmonics are generated. This command can only be sent
while the OUTPUT is OFF. If the OUTPUT is ON, an error is generated
and no change of state occurs. ("Unable to execute this action with
output enabled").
< 0 | OFF | 1 | ON >
<b>
INTH:STAT ON
[SOURce:]INTHarmonic:STATe?
Query format returns the interharmonic state setting.
<b>
INTH:STAT?
1