Power On Settings; Program Output Parameters; Table 6-2: Available Output Parameters On Program Screen - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

6.4.1

Power On Settings

The AFX Series will normally power up with the last settings in effect at turn-off for units
with firmware revision 1.6.0 or higher. Older firmware units will come up with factory
default settings.
Starting from firmware revision 1.6.0, this behavior is determined by the the
"SOURce:INITial" command. This feature is active by default. This makes the AFX
"remember" all the settings after cycling power.
This mode can be disabled by using the remote control command:
SOURce:INITial 0
This setting is retained in non-volatile (FLASH) memory.
6.4.2

PROGRAM Output Parameters

The two data entry methods described apply to the parameters on the main PROGRAM
screen. This includes those shown in the table below.
PARAMETER
Frequency
Phase
Voltage AC
Voltage DC
Current limit
Power limit
kVA limit
Each screen has up to five soft keys on the right hand side of the display. These may change
as the selected parameter changes. To move between parameter fields in any screen, use
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Figure 6-2: PROGRAM Screen
Range
15 - 1200
0.0 – 359.0
0 – 300
0 - 425
0 to Max
0 to Max
0 to Max

Table 6-2: Available Output Parameters on PROGRAM screen

AFX SERIES® OPERATION MANUAL
SECTION 6:
Unit
Description
Hz
Output frequency
Degrees
Phase angles for phase B and C
V rms
AC output
Vdc
DC output
A rms
RMS Current Limit
W
True Power Limit
VA
Apparent Power Limit
Front Panel Operation
Page 110 of 485