Query Format
Description
Parameters
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
PROGram:EXECuted:TT? [,<nr1>] [,<cr>]
This command returns the Transient Table settings of the executing
program only. The steady state table data is not returned.
Option: STYLE [,<nr1]
0 = Human readable Style A (default if omitted)
1 = Human readable Style B
2 = Binary Data Format. Can be more useful to search for differences
between programs.
See PROGram:TT? Command for formats
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:EXEC:TT? 2
-> transient table program data
PROGram[:SELected]:CHECK? [,<nr1>] [,<cr>]
This command performs a check on the selected program steady
state and transient tables looking for the following conditions:
Hardware Limit violations
User Limit violations
Saturation limits.
If no violations are present, this command returns OK and the
program can be executed without generating any errors. If the
selected program cannot be run due to one or more issues with its
content, one or more errors detailing the issues will be returned.
For example, if the upper voltage user limit is set to 100V and the
program contains a setting of 300V, a "Cannot load program, Run
PROGRAM:CHECK?" error will be generated when attempting to
execute this program. When sending the PROGRAM:CHECK? Query,
the response will be "VOLT1 AC voltage set point cannot change due
to user limit".
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:CHECK?
VOLT1 AC voltage set point cannot change due to user limit
PROGram:EXECuted:CHECK? [,<nr1>] [,<cr>]
This command serves the same purpose as the PROG:CHECK?
Command but applies to a program that is executing.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:EXEC:CHECK?
VOLT1 AC voltage set point cannot change due to user limit