AFX Series Power Source Operation Manual
[SOURce:]IMPEDance:L
This command sets the L value for the output impedance. Available
programming range is
-0.00000000
<L>
<nr2>
IMPED:L 0.00002
[SOURce:]IMPEDance:L?
<nr2>
IMPED:L?
0.00002
[SOURce:]IMPEDance:L[:LIMit]:MAXimum?
This command return the maximum allowable setting value for the L
component of the output impedance.
None
N/A
IMPED:L:MAX?
0.00005000
[SOURce:]IMPEDance:L[:LIMit]:MINimum?
This command return the minimum allowable setting value for the L
component of the output impedance.
None
N/A
IMPED:L:MIN?
0.00000000
[SOURce:]IMPEDance:MODE
This command sets the programmable impedance mode to either
Real-Time mode (0) or RMS Mode (1). See page 161 for a description
of both impedance modes.
0
Real mode.
1
RMS mode.
Note: To change programmable impedance modes, the output of
the power source must be turned OFF first. Trying to change
modes while the output is ON will result in an error message.
< 0 | 1 >
<b>
IMPED:MODE 1
[SOURce:]IMPEDance:MODE?
<b>
IMPED:MODE?
1
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8:
~
0.00005000
(Henry).