AFX Series Power Source Operation Manual
Category
Error Message
Error
Line to line
measurements only
available with sinewaves.
Error
Digital I/O interface
conflict: Single-Phase
relay control is active.
Error
Digital I/O interface
conflict: Single-Phase
relay cannot change with
output enable.
Error
Digital I/O interface
conflict: Single-Phase
relay cannot change due
relay closed.
Error
Unable to disable output.
One or more inverter
stages failed to disable.
Error
Internal battery needs to
be replaced.
Error
Serial number mismatch:
Front panel does not
match power stages.
Error
Suffix not allowed in
single form.
Error
Suffix not allowed in split
form.
Error
Peak current limit setting
is too low for the desired
voltage and frequency.
Error
Program transient trigger
input is disabled.
Error
Steady state not yet
stabilized.
AFX SERIES® OPERATION MANUAL
Service and Maintenance
SECTION 13:
Possible Cause
with Output Control
Switch (OCS) option
which always enables
Remote Inhibit
Measurement not
available. Line to Line
voltage measurements
can be calculated from L-
N and Phase Angles only
when all phase
waveforms are Sine
Setting conflict
Setting conflict. Changing
Phase mode only allowed
when Output is OFF
Setting conflict
Output OFF failed as one
of more inverters could
not be disabled
Warning. Front panel
controller battery low.
Setting conflict. Front
panel does not match
power stages serial
number
Setting conflict.
Command suffix invalid
for Single Phase mode
Setting conflict.
Command suffix invalid
for Split Phase mode
Setting conflict. Peak
current limit setting too
low to support requested
voltage and frequency.
AFX has a minimum peak
limit because it affects
output inductor current
and at high frequencies, a
circulating current
proportional to the
voltage and frequency
occurs.
Setting conflict. External
Trigger Input disabled
??
Resolution
Set all phases to use SINE
waveform #1.
Turn Output OFF
Turn Unit off with Circuit
Breaker
Error could be result of
reverting to older
firmware version. If so,
use SANITIZE command
to clear this error.
Contact customer service
Change phase mode
Change phase mode
Increase the peak current
limit setting
Enable External Trigger
Input
??