Dedicated Function Digital Inputs - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

7.3.5

Dedicated Function Digital Inputs

Remote Inhibit
External Trigger Input
External Phase Sync Input
7.3.5.1
Remote Inhibit
The mode can be selected from the SYST (SYSTEM) menu screen using the Interfaces,
Remote Inhibit selection as shown below.
There are three modes of operation for this input:
4. Disable mode: In his mode, the Remote Inhibit inputs are not active so this function
is turned off. No short between the RI pins is required to enable the output in this
mode.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Rear Panel, Connectors and Protection
SECTION 7:
REMOTE
INHIBIT
AFX SERIES® OPERATION MANUAL
Page 193 of 485