Query Syntax
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
[SOURce:]STEP:RAMP:DEFault?
This command returns default set value for the STEP ramp time
setting.
<nr2>
STEP:RAMP:DEF?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:LENGth <time>, <opt>
This command sets the ramp time of the step in seconds
Minimum time set value allowed is 0.0002 sec. (0.2 msec)
Time in seconds, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr2>, <cr>
STEP:MODE:LENG 5, SAT
[SOURce:]STEP:LENGth?
<nr2>
STEP:LENG?
5.0000, SAT
[SOURce:]STEP:LENGth:MINimum?
This command returns lowest permissible set value for the STEP
length time setting.
<nr2>
STEP:LENG:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:LENGth:MAXimum?
This command returns highest permissible set value for the STEP
length time setting.
<nr2>
STEP:LENG:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP: LENGth:DEFault?
This command returns default set value for the STEP length time
setting.
<nr2>
STEP:LENG:DEF?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings