Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
[SOURce:]PROTect:PEAK:CURRent:LEVel <LEVEL>
This command sets the peak current protection level.
< LEVEL >
<nr2>
PROT:PEAK:CURR:LEV 95.0
[SOURce:]PROTect:PEAK:CURRent:LEVel?
<b>
PROT:PEAK:CURR:LEV?
95.0000
[SOURce:]PROTect:PEAK:CURRent:LEVel:MAXIMUM?
This query command returns the maximum allowable setting for the
peak current protection level.
<nr2>
PROT:PEAK:CURR:LEV:MAX?
104.0000
[SOURce:]PROTect:PEAK:CURRent:LEVel:MINIMUM?
This query command returns the minimum allowable setting for the
peak current protection level.
<nr2>
PROT:PEAK:CURR:LEV:MIN?
104.0000
[SOURce:]PROTect:PEAK:CURRent:LEVel:DEFault?
This query command returns the default setting for the peak current
protection level.
<nr2>
PROT:PEAK:CURR:LEV:DEF?
104.0000
[SOURce:]PROTect:PEAK:CURRent:TRIPped?
This query command returns tripped state of the peak current
protection level funtion. Return 1 if tripped, 0 if not.
<b>
PROT:PEAK:CURR:TRIP?
1
[SOURce:]PROTect:PEAK:CURRent:TRIPped:CLEar
This command clears the the peak current protection protection
tripped status.
None
n/a
PROT:PEAK:CURR:TRIP:CLE
AFX SERIES® OPERATION MANUAL
Remote Control Programming
SECTION 8: