T Option Chassis Rear Panel Connectors - Pacific Power Source AFX Series Operation Manual

Programmable power source
Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

5.21.5 T Option Chassis Rear Panel Connectors

There are several connectors located on the rear panel of the Transformer chassis that are
used to route power and voltage sense as well as Auxiliary I/O signals used to control the
transformer option. Refer to figure below.
Legend for rear panel connectors is shown in the table below.
Call Out
1
2
3
4
5
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
LABEL
DIGITAL & ANALOG I/O
FROM MASTER
EXTERNAL VOLTAGE SENSE -
ANBNCN
EXTERNAL VOLTAGE SENSE -
FROM MASTER
INPUT FROM MASTER
AFX SERIES® OPERATION MANUAL
SECTION 5: UNPACKING AND INSTALLATION
Description
Auxiliary I/O connector pass-through from Master
AFXT. This connector may be used to access any
Auxiliary I/O connections that are not reserved for
Transformer option control.
Auxiliary I/O connection from master AFXT power
source Auxiliary I/O connector. Use the provided
DB25 Male-Female cable to connect the Master Aux
I/O connector to the Transformer chassis.
External Voltage Sense Connector. Connect to load
for external voltage sense. Note that the External
Voltage sense connector on the master AFX unit is
not accessible when the transformer option is
installed.
External Voltage Sense connection from master AFX
External Voltage Sense connector. Use the sense
wire harness to connect the Master AFXT External
Voltage Sense to the Transformer chassis using this
connector.
Power input from Master AFX to Transformer
Chassis. Connect the provided Power Wire Harness
from the Master AFX output connector to the
Transformer chassis using this connector.
Page 101 of 485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents